@jctrout, you are correct, i was too lazy to open the anns and went from memory
Assuming entire 5.5" liner was full of cement, around 32,500l or 200 bbl of cement was displaced into the annulus.
...the annular volume b/w 8.5" hole and 5.5" liner? - 21.3 l per metre according to tables.
So that means around 1438 m of annulus was filled above the 4220 mark (ive allowed for cement in the base 54 m of hole) . i.e. cement went up to 2782 m depth. If you look at@Ya earlier post, the cement would have made it into the 9" casing (set at 3,097m), assuming im correct. (ive not altered volume for 9" casing, i just wanted to see whether it made it to the 9" casing.