    To answer a few questions from above posts.

    Abandonment Pressure

    Gas fields can be put on compression, so can be produced down to a low pressure (if economic to do so). The lower the pressure in the tubing, the lower the gas density so lower gas hydrostatic pressure.

    Tubing Size

    Some one above mentioned 4-1/2" tubing.

    I assume they used this so reasonable sized thru tubing perforating guns can be deployed for the upper zones. To save pulling the tubing and rerunning will TCP (tubing deployed guns).

    5 MMscfd is a tiny gas rate up 4-1/2" tubing wrt efficiently lifting liquids. So they could have had slugging flow during the cleanup period

    Choke Size

    Looking at the breakdown in pressures in my earlier post, I should have mentioned that not alot was to be gained by using a larger choke size. They were only holding 970psi. Reducing it to 500psi would increase the drawdown by about 400 psi, but because the drawdown was already high (low productivity index), maybe would have attained only an extra 10% flow rate.

    Note, I'm a non holder at present. Might come across after the "April sun in Cuba" is concluded.

    SS
 
watchlist Created with Sketch. Add BRU (ASX) to my watchlist
(20min delay)
Last
8.2¢
Change
0.000(0.00%)
Mkt cap ! $55.05M
Open High Low Value Volume
8.3¢ 8.3¢ 8.2¢ $1.175K 14.27K

Buyers (Bids)

No. Vol. Price($)
1 100000 7.9¢
 

Sellers (Offers)

Price($) Vol. No.
8.2¢ 6315 2
View Market Depth
Last trade - 13.08pm 12/07/2024 (20 minute delay) ?
BRU (ASX) Chart
arrow-down-2 Created with Sketch. arrow-down-2 Created with Sketch.