KPO 0.00% 1.0¢ kalina power limited

More Info from KPO, page-407

  1. 2,218 Posts.
    lightbulb Created with Sketch. 946
    A bit off the recent topic, but the following link is from the company (Kaishan Group, china) that did the ORC project at Sinopec Hainan branch/island in 2014 as an alternative solution due to the delay of Kalina project by then Wasabi & SSNE (as mentioned in the quoted post).
    The link below shows some features of this ORC project and a photo of this plant ( screenshot from their case study brochure in chinese)

    Sinopec Hainan Oil Refining and Chemical Hot Water Application

    Sinopec Hainan Oil Refining and Chemical is the first application in the world – two ORC plant working in series with the hot water as the heat source. They supply of hot water flow rate is 200 t/h with 118℃ temperature. The installation output of first part is 1,300 kW. It can generate 4.63 kWh per ton water under ambient temperature 24.9℃, and the net power generation is up to 70%.
    Kerry® ORC screw expander power plant:

    Working in series        
    1 High temperature Low temperature Total Benefits    
    2 Evaporating temperature        
    3 101℃
    81℃
         
    4 Installed power        
    5 710 kW
    630 kW
         
    6 Voltage Sepc        
    7 6,300 V
    6,300 V
         
    8 Net Output ambient temp 34℃
    438 kW
    351 kW
    789 kW
    9 ambient temp 24.9℃
    503 kW
    424 kW
    927 kW
     
    10 ambient temp 15.5℃
    544 kW
    478 kW
    1044 kW
     
    11 Annual Output ambient temp 34℃
    3,504,000 kW
    2,808,000 kW
    6,312,000 kW
    12 ambient temp 24.9℃
    4,024,000 kW
    3,392,000 kW
    7,416,000 kW
     
    13 ambient temp 15.5℃
    4,352,000 kW
    3,824,000 kW
    8,176,000 kW
     
    14 Annual Production ambient temp 34℃
    420.48 K
    336.96 K
    757.44 K
    15 ambient temp 24.9℃
    482.88 K
    407.04 K
    889.92 K
     
    16 ambient temp 15.5℃
    522.24 K
    458.88 K
    981.12 K
     
    17 Annual CO2 discharge reduction ambient temp 34℃
    1,829 Ton
    1,466 Ton
    3,295 Ton
    18 ambient temp 24.9℃
    2,100 Ton
    1,770 Ton
    3,870 Ton
     
    19 ambient temp 15.5℃
    2,272 Ton
    1,996 Ton
    4,268 Ton
     
    20 Net Generation Per ton Water ambient temp 34℃
    3.95 kWh
       
    21 ambient temp 24.9℃
    4.63 kWh
         
    22 ambient temp 15.5℃
    5.10 kWh
         
    • 34℃ is the hottest month average temperature, 24.9℃ is the annual average temperature, 15.5℃ is the coolest month average temperature.
    • Average working hour is 8,000 hours.
    • The electricity price is US$0.12/KWh.
    • To generate 1 KWh power discharge 0.522 kg CO2 (The Bureau of Energy of Taiwan, 2012)
    [/IMG]
    http://i68.tinypic.com/2lsb8th.jpg

    Some serious competitors out there, hurry up Kalina!

    DYOR.
    Last edited by hkhf: 09/04/17
 
watchlist Created with Sketch. Add KPO (ASX) to my watchlist
(20min delay)
Last
1.0¢
Change
0.000(0.00%)
Mkt cap ! $27.39M
Open High Low Value Volume
1.0¢ 1.1¢ 1.0¢ $2.005K 192.7K

Buyers (Bids)

No. Vol. Price($)
8 2040039 1.0¢
 

Sellers (Offers)

Price($) Vol. No.
1.1¢ 1888787 3
View Market Depth
Last trade - 15.58pm 15/11/2024 (20 minute delay) ?
KPO (ASX) Chart